Icu up to 55 kA at 415 V, Standard Breaking Capacity N [13659] Siemens

:

:

. VL 800N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 800A, RATED CURRENT IR= 320...800A, OVERLOAD PROTECTION, ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND . .
146,420.00
. VL 800N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 800A, RATED CURRENT IR= 320...800A, OVERLOAD PROTECTION, ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND . . WITH SAFETY LABEL FOR USA
148,120.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
129,480.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
131,180.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
151,260.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
152,960.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
151,260.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
152,960.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . .
127,060.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
128,760.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . AUXILIARY SWITCH KIT 4HS(2NO+2NC) WITH SAFETY LABEL FOR USA
133,040.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT 24 V DC AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
137,720.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT 208 - 277 V AC AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
137,720.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . .
147,630.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
149,330.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
151,310.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . .
147,630.00
. VL 800N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
149,330.00
. VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DN . .
196,430.00
. VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DN . . WITH SAFETY LABEL FOR USA
198,140.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
174,250.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
175,950.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
204,500.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
206,210.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
204,500.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
206,210.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . .
170,620.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
172,320.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT 208 - 277 V AC AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
181,280.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . .
201,680.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
203,380.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . .
201,680.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
203,380.00
. VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV . .
222,650.00
. VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV . . WITH SAFETY LABEL FOR USA
224,360.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
196,430.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
198,140.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
235,960.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
237,670.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
235,960.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
237,670.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . .
194,010.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
195,720.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . .
233,140.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
234,840.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . .
233,140.00
. VL 1250N . .. ICU=50KA / 415 V AC 3 ., ETU22, LSIG 3. S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT . . WITH SAFETY LABEL FOR USA
234,840.00
. VL 1600N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV A . .
299,290.00
. VL 1600N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION . . ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV A . . WITH SAFETY LABEL FOR USA
300,990.00
. VL 1600N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH
263,390.00
. VL 1600N . .. ICU=50KA / 415 V AC 3 ., ETU20, LSI IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY WITHOUT AUXILIARY/ALARM SWITCH WITH SAFETY LABEL FOR USA
265,090.00