SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480 V 3 AC, 12 A controllable: Field rectifier D500/15 MREQ-GEG6V62 Output: 500 V DC, 15 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480 V 3 AC, 12 A controllable: Field rectifier D500/15 MREQ-GEG6V62 Output: 500 V DC, 15 A L05=Electronics power supply for connection to 24 V DC S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 25A controllable: Field rectifier D420/30 MREQ-GEG6V62 Output: 420 V DC, 30 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 25A controllable: Field rectifier D500/30 MREQ-GEG6V62 Output: 500 V DC, 30 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 25A controllable: Field rectifier D500/30 MREQ-GEG6V62 Output: 500 V DC, 30 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 25A controllable: Field rectifier D500/30 MREQ-GEG6V62 Output: 500 V DC, 30 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 25A controllable: Field rectifier D500/30 MREQ-GEG6V62 Output: 500 V DC, 30 A G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 400V 3AC, 50 A controllable: Field rectifier D485/60 MRE-GEE6S22 Output: 485 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 50 A controllable: Field rectifier D420/60 MREQ-GEG6V62 Output: 420 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 50 A controllable: Field rectifier D575/60 MRE-GEE6S22 Output: 575 V DC, 60A G00=Advanced CUD on left G20=CBE20 PROFINET module on left L10=Without field power unit S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 50 A controllable: Field rectifier D575/60 MRE-GEE6S22 Output: 575 V DC, 60A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 50 A controllable: Field rectifier D575/60 MRE-GEE6S22 Output: 575 V DC, 60A G00=Advanced CUD on left L05=Electronics power supply for connection to 24 V DC L10=Without field power unit S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 50 A controllable: Field rectifier D575/60 MRE-GEE6S22 Output: 575 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 50 A controllable: Field rectifier D500/60 MREQ-GEG6V62 Output: 500 V DC, 60A G00=Advanced CUD on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 50 A controllable: Field rectifier D500/60 MREQ-GEG6V62 Output: 500 V DC, 60A G00=Advanced CUD on left G20=CBE20 PROFINET module on left L11=2Q field power unit S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 50 A controllable: Field rectifier D500/60 MREQ-GEG6V62 Output: 500 V DC, 60A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 50 A controllable: Field rectifier D500/60 MREQ-GEG6V62 Output: 500 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 575V 3AC, 50 A controllable: Field rectifier D690/60 MRE-GEE6S22 Output: 690 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 575V 3AC, 50 A controllable: Field rectifier D600/60 MREQ-GEG6V62 Output: 600 V DC, 60A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 400V 3AC, 75A controllable: Field rectifier D485/90 MRE-GEE6S22 Output: 485 V DC, 90A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 75A controllable: Field rectifier D420/90 MREQ-GEG6V62 Output: 420 V DC, 90A G00=Advanced CUD on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 75A controllable: Field rectifier D420/90 MREQ-GEG6V62 Output: 420 V DC, 90A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 75 A controllable: Field rectifier D575/90 MRE-GEE6S22 Output: 575 V DC, 90A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 75 A controllable: Field rectifier D575/90 MRE-GEE6S22 Output: 575 V DC, 90A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 75 A controllable: Field rectifier D575/90 MRE-GEE6S22 Output: 575 V DC, 90A L10=Without field power unit M08=Assembled PCBs, painted S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 75 A controllable: Field rectifier D500/90 MREQ-GEG6V62 Output: 500 V DC, 90A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 75 A controllable: Field rectifier D500/90 MREQ-GEG6V62 Output: 500 V DC, 90A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 75 A controllable: Field rectifier D500/90 MREQ-GEG6V62 Output: 500 V DC, 90A L10=Without field power unit M08=Assembled PCBs, painted S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 75 A controllable: Field rectifier D500/90 MREQ-GEG6V62 Output: 500 V DC, 90A S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 400V 3AC, 104A controllable: Field rectifier D485/125 MRE-GEE6S22 Output: 485 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 104A controllable: Field rectifier D420/125 MREQ-GEG6V62 Output: 420 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 104A controllable: Field rectifier D575/125 MRE-GEE6S22 Output: 575 V DC, 125 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 104A controllable: Field rectifier D575/125 MRE-GEE6S22 Output: 575 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left L05=Electronics power supply for connection to 24 V DC L10=Without field power unit S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left M08=Assembled PCBs, painted M10=Nickel-plated copper busbars S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left L05=Electronics power supply for connection to 24 V DC L10=Without field power unit M08=Assembled PCBs, painted S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left L10=Without field power unit M08=Assembled PCBs, painted S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 104A controllable: Field rectifier D500/125 MREQ-GEG6V62 Output: 500 V DC, 125 A L10=Without field power unit S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 575V 3AC, 104A controllable: Field rectifier D690/125 MRE-GEE6S22 Output: 690 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 575V 3AC, 104A controllable: Field rectifier D600/125 MREQ-GEG6V62 Output: 600 V DC, 125 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 400V 3AC, 174A controllable: Field rectifier D485/210 MRE-GEEF6S22 Output: 485 V DC, 210 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 400V 3AC, 174A controllable: Field rectifier D420/210 MREQ-GEGF6V62 Output: 420 V DC, 210 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 174A controllable: Field rectifier D575/210 MRE-GEEF6S22 Output: 575 V DC, 210 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 174A controllable: Field rectifier D575/210 MRE-GEEF6S22 Output: 575 V DC, 210 A G00=Advanced CUD on left L10=Without field power unit S01=Memory card on left
SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 480V 3AC, 174A controllable: Field rectifier D575/210 MRE-GEEF6S22 Output: 575 V DC, 210 A G00=Advanced CUD on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 174A controllable: Field rectifier D500/210 MREQ-GEGF6V62 Output: 500 V DC, 210 A G00=Advanced CUD on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 174A controllable: Field rectifier D500/210 MREQ-GEGF6V62 Output: 500 V DC, 210 A G00=Advanced CUD on left G10=Standard CUD on right L05=Electronics power supply for connection to 24 V DC M08=Assembled PCBs, painted M10=Nickel-plated copper busbars S01=Memory card on left S02=Memory card on right
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 174A controllable: Field rectifier D500/210 MREQ-GEGF6V62 Output: 500 V DC, 210 A G00=Advanced CUD on left G20=CBE20 PROFINET module on left S01=Memory card on left
SINAMICS DCM DC converter for 4-quadrant drives Circuit (B6) A (B6) C Input: 480V 3AC, 174A controllable: Field rectifier D500/210 MREQ-GEGF6V62 Output: 500 V DC, 210 A G00=Advanced CUD on left L11=2Q field power unit S01=Memory card on left